Document Type
Dissertation
Degree
Doctor of Philosophy (PhD)
Major/Program
Biomedical Engineering
First Advisor's Name
Wei-Chiang Lin
First Advisor's Committee Title
Committee chair
Second Advisor's Name
Shuliang Jiao
Second Advisor's Committee Title
committee member
Third Advisor's Name
Jessica Ramella-Roman
Third Advisor's Committee Title
committee member
Fourth Advisor's Name
Richard Bone
Fourth Advisor's Committee Title
committee member
Fifth Advisor's Name
Armando Barreto
Fifth Advisor's Committee Title
committee member
Keywords
All-optical Ultrasound, Quantitative Ultrasound, Photoacoustics, Probe Beam Deflection, Ultrasound Imaging
Date of Defense
2-15-2021
Abstract
Ultrasound (US) is a well-established deep-tissue imaging modality in biomedicine. It distinguishes different tissue types based on their echogenicity, but this approach provides limited diagnostic sensitivity and accuracy. The majority of the US transducers nowadays rely on lead zirconate titanate (PZT) ceramic elements to transmit and receive ultrasound. Unfortunately, significant limitations arise from these transducers due to their frequency characteristics and complex fabrication process. A recently introduced technique, Quantitative Ultrasound (QUS) Measurement, shows a great promise to improve US-based tissue diagnosis, but it requires a transducer with a large spectrum bandwidth, which is a feature not available in PZT transducers.
Recent research has shown that optical methods for ultrasound generation and detection may overcome these limitations. The significant advantages provided by the optical approaches are the tunable center frequency, large spectrum bandwidth, high sensitivity, and miniaturization friendly. More importantly, they are exceptionally suitable for quantitative measurements.
The primary objective of this Ph.D. research is to develop an all-optical ultrasound transducer (AOUT) for quantitative ultrasound measurements and imaging and, eventually, for tissue characterization. In order to accomplish this goal, an optical ultrasound transmitter (OUT) and a sensitive optical refractometry ultrasound detector (RUD) were developed. For ultrasound generation, an OUT was designed and built based on the photoacoustic (PA) effect. The OUT developed consists of two-layer Candle soot-PDMS coated on a glass substrate and can generate a maximum pressure (Pmax) of 0.16 MPa, a center frequency (f0) of 35 MHz, and a spectrum bandwidth (fBW) of over 38 MHz. For ultrasound detection, a RUD was designed and built based on the probe beam deflection technique (PBD). The RUD developed in this study has a sensitivity of 55 Pa and an axial resolution of 0.27 mm.
By combining OUT and RUD, an AOUT was designed and fabricated. The imaging and the quantitative measurement capabilities of the AOUT were validated using three scattering phantoms. The reconstructed images show the profiles of the phantoms with reasonable accuracy, and the frequency spectra of the backscattering signals acquired from these phantoms were distinctively different, which confirms the feasibility of using AOUT to perform quantitative ultrasound measurements.
Identifier
FIDC009553
ORCID
https://orcid.org/0000-0002-6240-4532
Recommended Citation
Almadi, Mohamed Abdulrahman, "Development of All-Optical Quantitative Ultrasound Imaging System" (2021). FIU Electronic Theses and Dissertations. 4701.
https://digitalcommons.fiu.edu/etd/4701
Included in
Bioimaging and Biomedical Optics Commons, Biomedical Devices and Instrumentation Commons
Rights Statement
In Copyright. URI: http://rightsstatements.org/vocab/InC/1.0/
This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).